Thermelgy IoT Platform

processshape

Trace

Relevant and Accurate Measurement

processshape

Monitor

Micro-services enabled automatic analytics

processshape

Yield

Fast, Impactful &
Personalized

process

Value

For you, your clients and ourselves

Thermelgy Trace

15%

The installed base of smart meters will increase by 15% every year till 2025

50 % of decision makers

in IT, services, utilities, and manufacturing have either deployed IoT, or will deploy it in the next 12-24 months

$70 B

will be spent by global manufacturer on IoT solution by 2022

tMY IoT devices platform

feature

tMY Smart Meter (M3): Electrical + Thermal

  • Electrical & Thermal energy
  • Provision for 4-20 mA (4 channel)
  • RS 485 Modbus enabled
  • Provision for 4 channel RTDs
  • 4 Input feedback – Operational history, On/off time,
  • Provision for pulse flow meter – 1 channel
  • Offline data storage (greater than 1 yr data)
  • GPRS module (cloud connectivity)
  • Highly reliable data transmission
  • Measures Power factor, Current, Voltage, Harmonics, Energy consumption etc
  • Dimension: 90 X 90 mm (std MFM size)
  • Accuracy class: 0.5s
  • Graphical LCD – Customised content

tMY IAQ sense (Air RH, Temp, VOC, CO2, PM1, PM2.5 and PM10)

  • 8 in ONE sensor
  • BME680 is a digital 4-in-1 sensor
  • Gas, humidity, pressure and temperature
  • RoHS compliant, halogen-free, MSL1
  • ISO16000-29 standard “Test methods for VOC detectors”
  • Gas pressure principal is used for VOC
  • Ethane, Ethanol, Acetone, CO, Isoprene, 3 Butadiene.
  • Outgassing from paint, furniture and/or garbage, high VOC levels due to cooking, food consumption, exhaled breath and/or sweating, Cosmetics etc
  • Operating Temp: -40 to 50 C
feature
feature

tMY IAQ sense (RH/Temp and VOC )

  • BME680 is a digital 4-in-1 sensor
  • Gas, humidity, pressure and temperature
  • RoHS compliant, halogen-free, MSL1
  • ISO16000-29 standard “Test methods for VOC detectors”
  • Gas pressure principal is used for VOC
  • Ethane, Ethanol, Acetone, CO, Isoprene, 3 Butadiene.
  • Outgassing from paint, furniture and/or garbage, high VOC levels due to cooking, food consumption, exhaled breath and/or sweating, Cosmetics etc
  • Operating Temp: -40 to 50 C
feature

tMY Gateway

  • Provision for 4-20 mA (2 channel)
  • RS 485 Modbus enabled
  • Offline data storage (greater than 1 yr data)
  • GPRS, Wi-Fi and LORA enabled module
  • Highly reliable data transmission
  • It can connect to any RS -485/Modbus-RTU protocol
  • Dimension: 50 X 50 mm (std MFM size)
  • 10 devices can be connected to one device (Energy meters, Heat meters, RTDs)
  • Flexible mounting options

tMY Controller

  • 14 channel relay outputs (Can directly control compressor, pumps, fan, chiller, AHUs etc)
  • 8 sensor inputs (Thermistors -50K and 5K)
  • 3 Phase voltage detection
  • HMI – Graphical LCD, 6 switches
  • Extendable wirelength
  • Expansion valve provision for two channels
  • Designed for two circuit heat pumps
  • Configurable dip switches
  • GPRS module (cloud connectivity)
  • Highly reliable data transmission
  • Offline data storage (greater than 1 yr data)- *.csv format
  • 4-20 mA (4 channel)
feature
feature

tMY Controller

  • 14 channel relay outputs (Can directly control compressor, pumps, fan, chiller, AHUs etc)
  • 8 sensor inputs (Thermistors -50K and 5K)
  • 3 Phase voltage detection
  • HMI – Graphical LCD, 6 switches
  • Extendable wirelength
  • Expansion valve provision for two channels
  • Designed for two circuit heat pumps
  • Configurable dip switches
  • GPRS module (cloud connectivity)
  • Highly reliable data transmission
  • Offline data storage (greater than 1 yr data)- *.csv format
  • 4-20 mA (4 channel)